-
Wind Sensing
Sniffer4D Multi-gas Sensing
Sniffer4D GHG (CO2 & CH4) Sensing
Speedip V2 Smart Water Sampling
Aerial Gas Sampling
Nuclear Radiation Sensing
Versatile & Powerful Generalists
Towards Carbon Neutrality
No More Rope Tangling & Full Automation
Close the "Sense→Sample→Lab Test" Loop
Sense while Flying
Assess the Scene from a Safer Distance
Ship Fuel Sulfur Content (FSC) Estimation
High FSC Ship Quick Screening
UAV-based Environmental Data Acquisition Solutions
Sniffer4D Mapper software visualizes and analyzes data from one or multiple Sniffer4D(s) in real-time, providing intuitive & insightful information for decision makers.
Sniffer4D Mapper - The Data Visualization and Analytical Software
Sniffer4D is able to sense up to 9 gases and particle concentrations at one time. Users can flexibly choose or alter their sensor configurations that suit their applications and budgets.
Ambient Air Monitoring
PM2.5 | PM10 | SO2 | CO | NO2 | O3 | TVOC | Odor (OU)
Oil & Gas Plant Leak Detection TVOC | CH4 | H2S | SO2
HAZMAT TVOC | CH4 | CO | CO2 | Cl2 | O2 | NO2 | H2S
Available Parameters
TVOC | SO2 | CO | NO2 | O3 | PM1.0 | PM2.5 | PM10 | CxHy / CH4 /LEL | H2S | HCl | TSP/PM100 | NH3 | CO2 | HCN | H2 | PH3 | Cl2 | O2 | NO | Odor (OU) | High-Resolution CH4*
* Externally-mounted modules that do not occupy the internal space.
Sense Up to 9 Gases at a Time
Advanced Real-time Visualization
Sniffer4D Mapper software visualizes and analyzes data from one or more Sniffer4Ds in real-time. Three types of visualization (2D grid/2D isoline/3D point cloud map) provide intuitive & insightful information for decision makers.
From data collection to result delivery
One-stop Workflow
One-click Result Delivery
After a mission, simply click a button to generate a mission report containing key results, or a CSV datasheet containing all the raw data. Reporting your work has never been easier.
-
Data Learning
Compare long-term datasets from Sniffer4D and a local reference monitoring station (placed at the same location) to determine the calibration parameters.
Inject calibrating gases with known concentrations to determine the calibration parameters.
Calibrating Gas
Use local AQI information to roughly determine the calibration parameters.
Quick Adjustment
Every Sniffer4D is factory calibrated before shipped out. We recommend re-calibrating the device every 12 months. There are generally 3 ways to calibrate Sniffer4D.
Sniffer4D provides superior data quality and offers up to part-per-billion (ppb) detection resolution for specific modules.
Even gases in ppb-level concentration can be sensed and analyzed with accuracy.
Achieved through: Proprietary ultra-low-noise signal processing circuits; State-of-the-art sensing components;
Proprietary environmental and individual difference compensation algorithms; Rigorous quality control process.
Verified Data Quality
An Innovative Integration Solution
"Attach & Go" Ground-based Gas Sensing solution, an agile, simple, and non-damaging solution for quickly mounting Sniffer4D multi-gas and GHG systems to most ground vehicles.
Sniffer4D V2 + Sniffer4D Mapper + Official Ground Vehicle Integration Kit + Ground Vehicle
TDLAS Methane Sensing Module + Sniffer4D V2 + Sniffer4D Mapper + Official Ground Vehicle Integration Kit + Ground Vehicle
1 ppm NDIR CO2 Sensing System + Sniffer4D Mapper + Official Ground Vehicle Integration Kit + Ground Vehicle
Traditional Solutions
Traditional Solutions
Limited Detection Range
Traditional detection methods have difficulties in achieving large-scale detection due to complex emission sources in the city.
Low Efficiency
Traditional detection methods much depend on handheld devices, unable to finish large-area detection missions with efficiency.
Slow Response
Hard to locate emission sources with effective deployment in HAZMAT scenarios.
Low Quality Data
Limited gas information for a thorough data analysis.
Typical Applications
User Cases
Jingjiang Branch of the Ministry of Ecology and Environment Tracking and Locating Gas Emission Sources With "Attach & Go" Ground-based Gas Sensing Solution
14 sets of "Attach & Go" environmental monitoring equipment are applied to track and locate gas emissions sources around cities. Our system significantly improves the efficiency in regular air quality inspecting, urban emission sources locating, gas diffusion analysis etc.
安装于正上方,最大限度降低旋翼气流干扰
安装于正上方,最大限度降低旋翼气流干扰
Ground-based & UAV-based Solution For Locating O3 Emission Sources
With our intuitive and visualization real-time data from Sniffer4D Mapper, the Ground-based + UAV-based gas sensing solution helped local EPA accurately target O3 emission sources.
Marquette University
Research on Urban Traffic and Environmental Pollution
"Attach & Go" solution using a Sniffer 4D sensor mounted on a vehicle allows measurement of particulate matter (PM 1, 2.5 and 10), NH3, H2S, and O3+NO2 on main roads and highways in Milwaukee, offering insightful information to analyze the impact of traffic on air pollution in mid-sized cities before & after Covid-19 lockdowns.
Institute of Applied Ecology, Chinese Academy of Sciences Spatial Distribution Characteristics of Gases & Particulate Matter
Sniffer4D V2 on Ground Vehicles provides solid data for research on spatial distribution characteristics of gaseous pollutants (NO2 & SO2) and particulate matter inside a city in the heating season of Northeast China.
"Attach & Go" Ground-based Gas Sensing
Unleash Sniffer4D V2's potential and expand its application. Greatly reduce the cost of detecting, mapping & analysing hyperlocal air pollution
This website has been migrated to
'soarability.com'
After loading is complete, it will automatically redirect to the new website.
If you are unable to open it,
you can contact Soarability directly at the following email address
inquiry@soarability.tech
Email:inquiry@soarability.com
60 PAYA LEBAR ROAD #11-53 PAYA LEBAR SQUARE SINGAPORE (409051)
-
ꁸ 回到顶部
-
ꂅ 市场部 13728948398
-
ꁗ QQ客服
-
ꀥ 市场部微信